Huw Rodway, Global Re-Engineering Manager at Celeros Flow Technology, explains how taking reverse engineering a stage further and re-engineering parts when repairing pumps can offer a wide range of benefits.

Working with older flow control equipment can present challenges. For example, it can be difficult to source replacement parts for equipment that has existed for many years. Sometimes, the pump manufacturer is unknown, no longer in business or unwilling to support aged products.

Ensuring that spare parts are available for servicing equipment is key. However, how much time and effort is invested in locating spare parts? How frustrating is it to find pumps are obsolete? Would the traditional approach of replacing the worn parts with identical parts solve any issues or allow for any performance or reliability improvements to be implemented as part of the repair? Likewise, new replacement pumps can be an expensive solution, especially since it is not only the cost of a pump that needs to be considered. A plant may have a complex layout, and replacing associated pipework may not be practical.

Throughout a pump’s life, there may have been alterations in operating conditions, duty or the medium being pumped now differing from the original design requirements. Operating equipment outside its design parameters will accelerate and exacerbate wear, corrosion, cavitation, and erosion, resulting in pumps no longer performing as required and, ultimately, premature failure.
Going beyond simply replicating a part, a solution to addressing these challenges is ‘re-engineering’, but what exactly is involved? Part replication and reverse engineering generate like-for-like parts, potentially without any engineering assessment. Whilst this may deliver a spare part, it does nothing to address the root cause of any failure or poor performance experienced and could replicate the exact failure mechanisms.

By contrast, re-engineering takes a holistic pump repair and maintenance approach. By using an existing part only as a template and incorporating engineering input, mating part analysis, component design optimisation, modern materials and manufacturing techniques, the enhanced solution can have an extended service life and lower total cost of ownership.

Re-engineered components are offered on multiple levels, with several benefits:

  • Engineered replacement parts are a secure source of parts, particularly for obsolete items.
  • Upgraded enhanced parts can be designed to last longer and solve recurring issues.
  • Re-rated parts with altered hydraulic performance can realign a pump’s performance to current or future system requirements, extending its life.
  • Upgraded and re-rated parts offer maximum life, performance, and benefit.
    Therefore, whenever pumps require spare parts or repair, there is an opportunity to make changes, incorporating these additional benefits.

    Engineered replacement parts
    Perhaps the most apparent application of re-engineering is in being able to supply spare parts – particularly those that are no longer available or supported. Re-engineering ensures a secure supply route for all future spares, giving long-term assurance.  If a pump is deemed obsolete, it is likely that a replacement pump would have a different footprint, making installing a new pump with different dimensions problematic. Re-engineering an obsolete pump’s internal components and casing allows these parts to be supplied as and when required. This mitigates the requirement to purchase a complete replacement pump, and allows the retention of the existing base plate, footprint and auxiliary equipment, thus saving significant expense and possible infrastructure changes. This is likely the fastest and most cost-effective solution.
    The re-engineered parts can be designed to ensure replacement parts or sub-assemblies fit precisely with existing components. They can even be made compatible with a fleet of pumps, standardising parts to reduce inventory.

    Upgraded and enhanced parts
    What if the life of the components that require replacing could be increased? By reviewing the system and pump operations, carrying out route cause analysis of failures, and assessing current and future requirements and worn components, companies like Celeros FT that re-engineer parts can provide recommendations for mechanical and material improvements. For example, rotor dynamics can be optimised to increase asset reliability. This could include improvements to shaft stiffness and wear ring geometry and the addition of swirl brakes.

    The materials used for re-engineered parts can include increased corrosion and erosion resistance, which can extend service life and mean time between failure. Or hardened running surfaces can reduce wear and maintain efficiencies for longer, while modern composite materials can mitigate failures.Bearing life can be extended with an engineering review of current bearing arrangements, appropriate guarding on housings, water in oil monitoring, and using composite materials for line shaft bearings. Emission leakage can also be improved with upgrades from gland packing to mechanical seals and from component to cartridge seal assemblies.

    Re-rated parts
    What if changes to operational performance are desired but have not yet been implemented due to concerns regarding feasibility and any impact on a pump’s health and performance?
    Equipment efficiency can be improved to reduce running costs. Material enhancements, particularly of wear parts, can allow tighter running clearances, reducing recirculation losses while hydraulic surfaces can have efficiency coatings applied, reducing friction losses.

    A pump’s performance can be aligned to system characteristics to establish the best efficiency point and optimise the reliability curve. Output can be reduced to suit system or process changes. This may require the rotor to be de-staged or the impeller diameter reduced, or it could also include implementing a variable frequency drive. Similarly, the output can be increased. In either case, a detailed analysis of the impact on the motor and other drive train equipment would be undertaken.

    A rapid and robust process
    For Celeros FT, the re-engineering process begins with a customer consultation to review the equipment details, operational issues, and performance to determine potential solutions.
    Next, laser scanning is used to obtain data on the existing components – not just the parts intended to be replaced, but also mating parts. Component materials are then analysed to assess potential upgrades and ensure the compatibility of existing and replacement parts. The data captured at this stage is stored for future reference when there is a demand to supply a part. This methodology facilitates scanning parts when they are available for future requirements.

    Based on analysis of all the available data, new components are designed, material grades specified, and manufacturing quality plans are generated. 3D models are created to facilitate CADCAM and additive manufacturing for casting purposes. Computational fluid dynamics and finite element analysis benchmark and validate designs.

    Finally, parts are manufactured to stringent quality requirements, rotating components are balanced to applicable grades, pressure containing parts are hydrotested, and parts are QA/QC approved before being shipped or incorporated into an overhaul at a Celeros FT Service Centre.

    Adding Value
    One example where re-engineering added value to a customer of Celeros TF was a UK Oil & Gas operator that required a solution when its (2.5 MW) 12-stage BB3 sea water injection pump failed in service. The customer consultation defined that the pump, providing seawater injection duty to support field production, required a solution which increased the mean time between failure and optimised its performance.

    Celeros FT worked with the customer to improve critical features within the pump, including upgrading the mechanical seals and modifying the existing bearing housings to allow for the provision of bearing isolators.

    During a strip inspection, several impellers were shown to be damaged beyond repair. Even with the extensive damage, Celeros FT could re-engineer the hydraulic components appropriately.
    Damage to the rotating assembly had resulted in areas within the stationary components that needed repair. The large and heavy top and bottom half pump casings were repaired and machined back to the design intent, re-inspected and hydrotested to the project duty requirements.

    3D models of the pump casings were then used as the basis for the mechanical layout. Given the large number of stages, a thorough assessment needed to be completed to ensure full mechanical integration between the mating components, especially when both existing and re-engineered parts were being used. The shaft was re-engineered and upgraded, and a full rotor dynamic assessment of the pump unit, including a lateral critical speed analysis in accordance with API 610 Latest Edition, was completed. This assessment, coupled with an in-house performance test at full speed (4000rpm), pressure (>2000m head) and power, gave the customer confidence that the re-engineered and upgraded pump would perform as required.

    Conclusion
    To ensure critical flow equipment is working to its best, operators need to consistently evaluate equipment behaviour and act quickly to rectify any problems. Re-engineering can provide the appropriate engineered solution to overhaul, upgrade, renew or replace older legacy equipment, optimise operation, and simplify spare parts management – irrespective of pump brand – to minimise downtime, reduce total cost of ownership and save the expense and disruption of having to install new systems throughout a plant. chevron circle-right www.celerosft.com

 