System NPSH Available (NPSHa)
- Pe - Pressure available system inlet liquid level
- Pb - Barometric pressure
- PD - Vapour pressure of pumped fluid at the pump suction inlet
- p - Density of the pumped fluid at the pump suction inlet
- g - Local gravitational acceleration (9.81 m/s2)
- Ve - Inlet velocity at the system suction inlet
- Ze - Static level difference between system inlet liquid level and a reference level, the negative sign becoming applicable if the reference level is above the system inlet liquid.
- Hv - Friction loss in suction-side pipework